Verbindingslaan
Location
Vorst, België
About
Optimising acoustics in home studio and listening space in accordance with EBU standard 3276. Measuring and analysing the room to optimise speaker placement to reduce effects from SBIR on frequency response, as well as to locate optimal position of the available porous absorbers. Again, managed to reduce LF energy decay with wise placement of rather small amount of porous absorbers. The wooden slats and its construction method take care of mid and high frequency absorption. The tilted roof helps redirect first order reflections away from sweet spot.